A Trusted Technology for High Quality Multilevel Groundwater Monitoring Since 1996  

The Water FLUTe is a depth discrete multilevel groundwater monitoring and head measurement system for

use in overburden and bedrock groundwater assessments.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Highlights

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

or

 

 

Water FLUTe System Specifications

 

 

Installation: The Water FLUTe multilevel groundwater system is installed

in open bedrock wells via eversion, in a similar process as a blank liner

installation (Click Here for a basic installation overview or for a detailed

installation guide Click Here)The Water FLUTe can also be installed in

the overburden or unstable bedrock via sonic drilling.  


The installation of a Water FLUTe is affected by the depth and diameter

of the hole, the relative transmissivity of the hole, the depth to the water

table, and the rate at which water can be supplied to fill the liner. 

The system can be used for artesian situations with a heavy mud fill.


If the hole is too tight to allow the liner to push the water into the formation, the water can be pumped from beneath the liner using a pump tube emplaced in the hole before the liner installation.


Water FLUTe systems are usually installed in uncased boreholes. Installations into multi-screened cased holes are also common. Varying borehole diameters are accommodated from 3-30 inches. The Water FLUTe can be installed through smaller casing into larger open holes below the casing, or into "telescoped" casing. The liner is completely heat welded without the use of any glues. 
 

In most situations, the Water FLUTe installation takes less than one day.
Some installations have required less than one hour.

Once the liner is fully extended in the hole, the geometry looks like that in Figure 1.

Note, that due to the size of the large tubing and pumping hardware components of the system, the pump system is not everted into the borehole, but simply lowered as a tubing bundle following the liner to the bottom.

 

Sample Intervals: All samples collected from the Water FLUTe are drawn directly from the formation, without the potential for cross contamination or leakage as possible with packer based multi-level systems.  The Water FLUTe is capable of up to 15 ports per borehole depending on the hole diameter from 4 inches to greater and all intervals can be sampled and purged simultaneously.

Sampling the System:

After the Water FLUTe is installed, the formation water will flow from

the formation into the screen, sample port, and up the tubing on the

inside of the liner. The water then flows up through the first check valve

and up both legs of the "U" shaped tubing (pump tube and sample tube)

to a height equal to the head of the formation.  The water level can then

be measured in the pump tube from the surface prior to sampling with a

water level meter.

To purge and sample the Water FLUTe, a gas pressure is applied to the

pump tube at a pressure greater than the head of the formation. Once the

pressure is applied, the check first check valve closes, and the pressure

forces the water to flow through the second check valve and to the surface

through the sample tube. This process is repeated multiple times to both

purge the system and collect samples.            

 

For a detailed sampling procedure Click Here.

Head Measurements: The water table depth at each port can be measured with

a water level meter in the pump tube or, for continuous head measurements at each port, an air couple transducer (ACT) system or downhole pressure transducers can be used.  Click here for more information on the ACT system.

 

Well Completion: There is no need for an exterior seal with grout, sand or bentonite. The liner seals the entire hole and the water is drawn directly from the formation.  As such, there is no concern about the seal of granular materials in a slender annulus.

Warranty and Removability: The Water FLUTe system is fully warrantied and removable for other use of the borehole or easy abandonment by grouting the borehole.  


 

 

 

Our experience with Water FLUTe multilevel groundwater monitoring system now spans 21 years. Water FLUTe systems have been installed in 48 states in the U.S., and many foreign countries. More detailed descriptions and publications are available at Publications.

Additional Uses:

The Water FLUTe is well suited for detection of tracer arrivals in that the purge volumes are minimal and the sample is drawn directly from the formation. Because there is not an interior tubing bundle, a transparent liner version allows one to watch for the arrival of strongly dyed injections, such as potassium permanganate, using a borehole camera. That option requires a special polyester liner instead of the standard nylon liner.

 

A FLUTe method called a precise gradient measurement is available in order to measure vertical gradients within ~ 1mm between any two ports in the liner.
 

Because there is no field assembly and no annular sealing materials needed, and the system is fully removable by inversion from the borehole, the overall cost of the Water FLUTe system is often the least expensive multi-level sampling and head measurement option of the multi-level monitoring systems.

Click Here for Water FLUTe FAQs

12 Port Water FLUTe Installation to 600 FT and Simultaneous Pumping.  Installation took 4 hours to complete.

Figure 1. Water FLUTe Pumping System

All system components are compatible with VOC and PFC Sampling!

  Easily purge
    all sample       intervals at
    the same             time.
 
 Simultaneous       purging          allows for         discrete         samples to      be collected   while saving   time spent in       the field.           
Each purge stroke pumps roughly 1 gallon of water.